Alpha Bridge AQSFP-40G-ER4
Features
- Compliant with 40G Ethernet 3ba and 40GBASE-ER4 Standard
- QSFP+ MSA compliant
- Compliant with QDR/DDR Infiniband data rates
- Up to 2Gb/s data rate per wavelength
- 4 CWDM lanes MUX/DEMUX design
- Up to 40km transmission on single mode fiber (SMF)
- 5dB link insertion loss budget
- Commercial case temperature: 0°C to 70°C
- Maximum power consumption 5W
- LC duplex connector
- RoHS compliant
Applications
- 40GBASE-ER4 Ethernet Links
- Infini band QDR and DDR interconnect
- Client-side 40G Telecom connections
Absolute Maximum Ratings
Parameter | Symbol | Min | Typ. | Max | Unit |
Storage Ambient Temperature | TSTG | -40 | 85 | °C | |
Operating Case Temperature | TOP | 0 | 70 | °C | |
Power Supply Voltage | Vcc | -0.5 | 3.6 | V | |
Relative Humidity (non-condensation) | RH | 0 | 85 | % | |
Damaged Threshold , each Lane | THd | 3.8 | dBm |
Recommended Operating Conditions
Parameter | Symbol | Min | Typ. | Max | Unit |
Operating Case Temperature | TOP | 0 | 70 | °C | |
Power Supply Voltage | Vcc | 3.135 | 3.3 | 3.465 | V |
Data Rate, each Lane | 10.3125 | 11.2 | Gb/s | ||
Control Input Voltage High | 2 | Vcc | V | ||
Control Input Voltage Low | 0 | 0.8 | V | ||
Link Distance with G.652 | D | 40 | km |
Digital Diagnostic Functions
Parameter | Symbol | Accuracy | Units | Notes |
Temperature monitor absolute error | DMI_Temp | ±3 | ℃ Over operating temperature range | |
Supply voltage monitor absolute error | DMI _VCC | ±0.1 | Over full operating | |
V range | ||||
Channel RX power monitor absolute error | DMI_RX_Ch | ±2 | dB 1 | |
Channel Bias current monitor | DMI_Ibias_Ch | ±10% | mA | |
Channel TX power monitor absolute error | DMI_TX_Ch | ±2 | dB 1 |
Optical Characterstics
Parameter | Symbol | Min | Type | Max | Unit | Notes |
Wavelength Assignment | L0 | 1264.5 | 1271 | 1277.5 | nm | |
L1 | 1284.5 | 1291 | 1297.5 | nm | ||
L2 | 1304.5 | 1311 | 1317.5 | nm | ||
L3 | 1324.5 | 1331 | 1337.5 | nm | ||
Transmitter | ||||||
Side Mode Suppression Ratio | SMSR | 30 | dB | |||
Total Average Launch Power | PT | 10.5 | dBm | |||
Average Launch Power, each lane | PAVG | -2.7 | 4.5 | dBm | ||
Optical Modulation Amplitude (OMA) each | POMA | 0.3 | 5 | dBm | 1 | |
Difference in Launch Power between any Two Lanes (OMA) | Ptx,diff | 4.7 | dB | |||
Launch Power in OMA minus Transmitter and Dispersion Penalty (TDP) each lane | -0.5 | dBm | ||||
TDP, each lane | TDP | 2.6 | dB | |||
Extinction Ratio | ER | 5.5 | dB | |||
Relative Intensity Noise | RIN | -128 | dB/Hz | 12dB reflection | ||
Optical Return Loss Tolerance | TOL | 20 | dB | |||
Transmitter Reflectance | RT | -12 | dB | |||
Transmitter Eye Mask Definition (X1, X2, X3, Y1, Y2, Y3) | {0.25,0.4,0.45,0.25,0.28,0.4} | |||||
Average Launch Power OFF Transmitter each lane | Poff | -30 | dBm | |||
Receiver | ||||||
Damage Threshold, each lane | THd | 3.8 | dBm | 2 | ||
Average Receive Power, each lane | -21.2 | -4.5 | dBm | |||
Receiver Reflectance | RR | -26 | dB | |||
Receiver Power (OMA) each lane | 4 | dBm | ||||
Receiver Sensitivity (OMA) each lane | SEN | -19 | dBm | |||
Stressed Receiver Sensitivity (OMA) each lane | -16.8 | dBm | 3 | |||
Difference in Receiver Power between any Two Lanes (OMA) | Prx,diff | 7 | dB | |||
LOS Assert | LOSA | -35 | dBm | |||
LOS Deassert | LOSD | -20 | dBm | |||
LOS Hysteresis | LOSH | 0.5 | dB | |||
Receiver Electrical 3 dB upper Cutoff Frequency each lane | Fc | 12.3 | GHz |
Pin Assignment
PIN | Logic | Symbol | Description | Note |
1 | GND | Ground | 1 | |
2 | CML-I | Tx2n | Transmitter Inverted Data Input | |
3 | CML-I | Tx2p | Transmitter Non-Inverted Data output | |
4 | GND | Ground | 1 | |
5 | CML-I | Tx4n | Transmitter inverted Data Input | |
6 | CML-I | Tx4p | Transmitter Non-Inverted Data output | |
7 | GND | Ground | 1 | |
8 | LVTLL-I | ModSeIL | Module Select | |
9 | LVTLL-I | ResetL | Module Reset | |
10 | VccRx | +3.3V Power Supply Receiver | 2 | |
11 | LVCMOS-I/O | SCL | 2-Wire Serial Interface Clock | |
12 | LVCMOS-I/O | SDA | 2-Wire Serial Interface Data | |
13 | GNC | Ground | ||
14 | CML-O | Rx3p | Receiver Non-Inverted Data output | |
15 | CML-O | Rx3n | Receiver Inverted Data output | |
16 | GND | Ground | 1 | |
17 | CML-O | Rx1p | Receiver Non-Inverted Data Output | |
18 | CML-O | Rx1n | Receiver Inverted Data Output | |
19 | GND | Ground | 1 | |
20 | GND | Ground | 1 | |
21 | CML-O | Rx2n | Receiver Inverted Data output | |
22 | CML-O | Rx2p | Receiver Non-Inverted Data output | |
23 | GND | Ground | 1 | |
24 | CML-O | Rx4n | Receiver Inverted Data output | 1 |
25 | CML-O | Rx4p | Receiver Non-Inverted Data output | |
26 | GND | Ground | 1 | |
27 | LVTTL-O | ModPrsL | Module Present | |
28 | LVTTL-O | IntL | Interrupt | |
29 | VccTx | +3.3V Power Supply transmitter | 2 | |
30 | Vcc1 | +3.3V Power Supply | 2 | |
31 | LVTTL-I | LPMode | Low Power Mode | |
32 | GND | Ground | 1 | |
33 | CML-I | Tx3p | Transmitter Non-Inverted Data Input | |
34 | CML-I | Tx3n | Transmitter Inverted Data Output | |
35 | GND | Ground | 1 | |
36 | CML-I | Tx1p | Transmitter Non-Inverted Data Input | |
37 | CML-I | Tx1n | Transmitter Inverted Data Output | |
38 | GND | Ground | 1 |
Ordering Information
Model Number | Part Number | Voltage | Temperature |
AQSFP-40G-ER4 | OPCS-S40-13-CB | 3.3V | 0°C to 70 °C |