Alpha Bridge AQSFP28-100G-eLR4
This product is a 100Gb/s transceiver module designed for optical communication applications compliant to 100GBASE-LR of the IEEE 802.3ba standard. The module converts 4 input channels of 25Gb/s electrical data to 4 channels of LAN WDM optical signals and then multiplexes them into a single channel for 100Gb/s optical transmission. Reversely on the receiver side, the module DE multiplexes a 100 GB/s optical input into 4 channels of LAN WDM optical signals and then converts them to 4 output of electrical data. The central wavelengths of the 4 LAN WDM channels are 1295.56, 1300.05, 1304.58 and 1309.14nm as members of the LAN WDM wavelength grid defined in IEEE 802.3ba. The high-performance cooled LAN WDM DFB transmitters and high sensitivity PIN receivers provide superior performance for 100Gigabit Ethernet applications up to 20km links and compliant to optical interface with 100GBASE-LR4 requirements specified in IEEE 802.3ba Clause 88.
The Product is designed with form factor optical/electrical connection and digital diagnostic interface according to the QSFP+ Multi-Source Agreement (MSA). It has been designed to meet the harshest external operating conditions including temperature, humidity and EMI interference.
Features
- Hot pluggable QSFP28 MSA form factor
- Compliant to IEEE 3ba 100GBASE-LR4
- Digital diagnostic monitoring support
- Hot pluggable 38 pin electrical interface
- Transmitter cooled 4x25Gb/s LAN WDM DFB TOSA (1295.56, 05,1304.58, 1309.14nm)
- Receiver 4x25G PIN ROSA
- Maximum power consumption 4W
- LC duplex connector
- Supports 1Gb/s bit rate
- Up to 20kmreach for 652 SMF
- Commercial case temperature range of 0°C to 70°C
- Single 3V power supply
- RoHS-6 compliant
Application
- 100GBASE-LR4 100G Ethernet Links
- Infiniband QDR and DDR interconnects
- Datacenter and Enterprise networking
Absolute Maximum Ratings AQSFP28-100G-eLR4
Parameter | Symbol | Min. | Max. | Units | Note |
Storage Temperature | Ts | -40 | 85 | °C | |
Max Supply Voltage | Vcc | -0.5 | 3.6 | V | |
Relative Humidity | RH | 0 | 85 | % | 1 |
Damage Threshold, each Lane | THd | 5.5 | dBm | ||
Operating Case Temperature | TOP | 0 | 70 | °C |
Recommended Operating Conditions AQSFP28-100G-eLR4
Parameter | Symbol | Min. | Max. | Units | Typ. |
Case operating Temperature | Top | 0 | 70 | °C | |
Supply Voltage | Vcc | 3.135 | 3.465 | V | 3.3 |
Link distance with G.652 | D | 0.002 | 20 | KM | |
Data Rate, each lane | Gb/s | 25.78125 | |||
Data Rate Accuracy | -100 | 100 | ppm | ||
Control Input Voltage-High | 2 | Vcc | V | ||
Control Input Voltage-Low | 0 | 0.8 | V |
Transmitter Electro-optical Characteristics AQSFP28-100G-eLR4
Parameter | Symbol | Min. | Typ. | Max. | Units | Note |
Transmit wave lengths | L0 | 1294.53 | 1295.56 | 1296.59 | nm | |
L1 | 1299.02 | 1300.05 | 1301.09 | nm | ||
L2 | 1303.54 | 1304.58 | 1305.63 | nm | ||
L3 | 1308.09 | 1309.14 | 1310.19 | nm | ||
Signaling Speed per Lane | 25.78125± 100 ppm | Gb/s | ||||
Side-mode Suppression Ratio | SMSR | 30 | dB | |||
Total Average Launch Power | PT | 10.5 | dBm | |||
Average launch power, each Lane | PAVG | 0 | 4.5 | dBm | ||
Optical Modulation Amplitude (OMA), each lane | POMA | 0.5 | 4.5 | dBm | ||
Launch Power in OMA minus Transmitter and dispersion penalty (TDP), each lane | -2.3 | 3.6 | dBm | |||
Transmitter and Dispersion Penalty (TDP), each lane | TDP | 2.2 | dB | |||
Extinction Ratio | ER | 4 | dB | |||
Difference in Launch Power between any Two Lances (OMA) | Ptx,diff | 5 | dB | |||
RIN20OMA | RIN | -130 | dB/Hz | |||
Optical Return Loss Tolerance | TOL | 20 | dB | |||
Transmitter Reflectance | RT | -12 | dB | |||
Average Launch Power OFF Transmitter, each lane | Poff | -30 | dBm | |||
Mask margin | 5 | % | ||||
Transmitter eye mask definition {X1, X2,X3, Y1, Y2, Y3} | {0.25, 0.4, 0.45, 0.25, 0.28, 0.4} | 2 |
Receiver Electro-optical Characteristics AQSFP28-100G-eLR4
Parameter | Symbol | Min. | Typ. | Max. | Units | Note |
Average Receiver Power, each Lane | -12.6 | 4.5 | dBm | |||
Receiver power, each lane (OMA) | -3.5 | dBm | ||||
Receiver reflectance | RR | -26 | dB | |||
Difference in receive power between any two lanes (Average and OMA) | 5.5 | dB | ||||
Receiver sensitivity (AOP), each lane | SEN | -8.6 | dBm | 2 | ||
Stressed Receiver Sensitivity (OMA), each lane | -6.8 | dBm | 4 | |||
Receiver 3 dB electrical upper cutoff frequency, each lane | Fc | 31 | GHz | |||
Damage Threshold, each Lane | THd | 5.5 | dBm | 3 | ||
LOS Assert | LOSA | -30 | dBm | |||
LOS Deassert | LOSD | -13 | dBm | |||
LOS Hysteresis | LOSH | 0.5 | dB | |||
Conditions of Stress Receiver Sensitivity Test (Note 5) | ||||||
Vertical Eye Closure Penalty, each lane | 1.8 | dB | ||||
Stressed Eye J2 Jitter, each lane | 0.3 | UI | ||||
Stressed Eye J9 Jitter, each lane | 0.47 | UI |
Pin Descriptions AQSFP28-100G-eLR4
Pin | Symbol | Description | Notes |
1 | GND | Ground | 1 |
2 | Tx2n | Transmitter Inverted Data Input | |
3 | Tx2p | Transmitter Non-Inverted Data Input | |
4 | GND | Ground | 1 |
5 | Tx4n | Transmitter Inverted Data Input | |
6 | Tx4p | Transmitter Non-Inverted Data Input | |
7 | GND | Ground | 1 |
8 | ModSelL | Module Select | |
9 | ResetL | Module Reset | |
10 | Vcc Rx | +3.3V Power Supply Receiver | 2 |
11 | SCL | 2-wire serial interface clock | |
12 | SDA | 2-wire serial interface data | |
13 | GND | Ground | 1 |
14 | Rx3p | Receiver Non-Inverted Data Output | |
15 | Rx3n | Receiver Inverted Data Output | |
16 | GND | Ground | 1 |
17 | Rx1p | Receiver Non-Inverted Data Output | |
18 | Rx1n | Receiver Inverted Data Output | |
19 | GND | Ground | 1 |
20 | GND | Ground | 1 |
21 | Rx2n | Receiver Inverted Data Output | |
22 | Rx2p | Receiver Non-Inverted Data Output | |
23 | GND | Ground | 1 |
24 | Rx4n | Receiver Non-Inverted Data Output | |
25 | Rx4p | Receiver Inverted Data Output | |
26 | GND | Ground | 1 |
27 | ModPrsL | Module Present | |
28 | IntL | Interrupt | |
29 | Vcc Tx | +3.3V Power supply transmitter | 2 |
30 | Vcc1 | +3.3V Power supply | 2 |
31 | LP Mode | Lower Power Mode | |
32 | GND | Ground | 1 |
33 | Tx3p | Transmitter Non-Inverted Data Input | |
34 | Tx3n | Transmitter Inverted Data Input | |
35 | GND | Ground | 1 |
36 | Tx1p | Transmitter Non-Inverted Data Input | |
37 | Tx1n | Transmitter Inverted Data Input | |
38 | GND | Ground | 1 |
Ordering information AQSFP28-100G-eLR4
Model Number | Part Number | Voltage | Temperature |
AQSFP28-100G-eLR4 | OPCW-S20 -13-CBD | 3.3V | 0°C to 70 °C |